Real AEMS plan of synthetic Depot Golf: the two rows of earth-covered magazines, the three open stacks with their barricades, the storehouse LW-1 and the internal road - the same depot as the 3D view, drawn to scale. Per AASTP-1 Ed D - not for operational use.
Real AEMS screen · synthetic Depot Golf · AEMS b7a732a
DEMO · NOT FOR OPERATIONAL USE

Explosives safety planning, made visible.

Visual planning, explainable assessments and traceable documentation for explosives safety professionals.

3D illustration of a synthetic depot - not a real site

  1. 3D illustration: the same depot seen straight from above
    02 Draw the site to scale.
  2. 03 Every pair, measured.
  3. Real AEMS plan of synthetic Depot Golf, the same depot as the 3D view, drawn to scale
    04 The same depot, in AEMS. Real AEMS screen · synthetic Depot Golf · AEMS b7a732a

Signature showcase · real AEMS screens

From findings to a compliant depot.

Depot Golf as first drawn had four findings: an open stack too close to a house, a magazine drawn turned so that AEMS counted it and its neighbour as one site, detonators stored with shells, and a barricade that did not count for people protection. Two are fixed here by moves AEMS worked out with the storages the depot already has; the people-protection one is shown in 3D below. Every card is the app's own screen and words on a synthetic site.

Real AEMS verdict card for open stack OS-3: Not compliant. 1 of 29 neighbours is too close. Worst: H-6 needs 472 m, has 441.5 m (30.6 m short).
Step 1 · Find it

An open stack is too close to a house.

AEMS measures every pair on the site and shows which one falls short - and by how much.

1 of 29 neighbours is too close. Worst: H-6 needs 472 m, has 441.5 m (30.6 m short).

Real AEMS screen · synthetic Depot Golf · AEMS b7a732a · captured 27 Oct 2026 · per AASTP-1 Ed D - NOT FOR OPERATIONAL USE

Real AEMS advice, a draft to check: move DEM-10, 135 items, 1,350 kg, from OS-3 to OS-1 (140 m away). After it: OS-3 Compliant, OS-1 Compliant; OS-1 takes it, every distance kept, compliant under Table 5.
Step 2 · Fix it

One move, with the storages you already have.

AEMS works out the fix in whole items and checks it on the whole site. A draft for you to check - AEMS never applies it itself.

Move DEM-10 (Charge, demolition 10 kg (synthetic)) - 135 items, 1,350 kg - from OS-3 to OS-1 (140 m away). After it: OS-3 ✓ Compliant · OS-1 ✓ Compliant

Real AEMS screen · synthetic Depot Golf · AEMS b7a732a · captured 27 Oct 2026 · per AASTP-1 Ed D - NOT FOR OPERATIONAL USE

Real AEMS advice under AASTP-1 Table 5, a draft to check: move DET-1, 2,000 detonators, 4 kg, from earth-covered magazine A-2 to HW-1. After it: A-2 Compliant, HW-1 Compliant.
Step 3 · Keep it compatible

Detonators may not share this storage with the shells.

From the inventory, AEMS checks what may share a storage under AASTP-1 Table 5 - here electric detonators (group B) and 155 mm shells (group E) - and says where the items can go.

Move DET-1 (Detonator, electric (synthetic)) - 2,000 items, 4 kg - from A-2 to HW-1 (1202 m away). After it: A-2 ✓ Compliant · HW-1 ✓ Compliant

Real AEMS screen · synthetic Depot Golf · AEMS b7a732a · captured 27 Oct 2026 · per AASTP-1 Ed D - NOT FOR OPERATIONAL USE

Real AEMS verdict card for the whole Depot Golf: Compliant. All 12 storages are far enough from their neighbours. 0 not compliant, 12 compliant.
Step 4 · All clear

Every storage, every pair - compliant.

With the fixes in place, the whole depot meets its distances and its compatibility rules.

All 12 storages are far enough from their neighbours.

Real AEMS screen · synthetic Depot Golf · AEMS b7a732a · captured 27 Oct 2026 · per AASTP-1 Ed D - NOT FOR OPERATIONAL USE

The real screen

This is AEMS.

Depot Golf after the fixes, exactly as the app shows it. Choose a part to look closer.

Real AEMS screen of the synthetic Depot Golf after the fixes: the depot on its plan, and the panel with the site verdict Compliant - all 12 storages far enough from their neighbours - and every storage listed as Compliant.

The whole window: the plan of the depot on the left, the verdict and every storage on the right.

Real AEMS screen · synthetic Depot Golf · AEMS b7a732a · captured 27 Oct 2026 · per AASTP-1 Ed D - NOT FOR OPERATIONAL USE

Depot Golf in 3D

Who the lines protect.

  1. AEMS draws the lines.

    From what is in each storage, AEMS draws two safeguarding lines round the depot: amber for inhabited buildings, blue for vulnerable ones such as schools and hospitals.

  2. The school and the hospital stand outside the blue line.

    Vulnerable buildings get the wider line. Both stand beyond it.

  3. Every house in the village stands outside the amber line.

    Fields lie between the line and the houses.

  4. House H-6 stands outside the amber line - after the fix.

    As first drawn an open stack was too close. After the move AEMS advised, the line passes just short of the house.

  5. Roads and the power line are checked too.

    AEMS checks the closest point of every road and power line against every storage. The closest calls, each with room to spare:

  6. Does the barricade count?

    Lines of sight run from the top of one stack to the other; AEMS adds up the barricade on each. Concrete used with earth counts four times its thickness (AASTP-1 2.2.3.3). AEMS: "BAR-02 with BAR-03: 10.3 m on line AB (1.0 m concrete × 4 + 6.3 m earth), 9.4 m 0.3 m above it".

  7. People protection: does the barricade count?

    LW-1, a light-walled storehouse, has an earth-backed concrete barricade towards the farm FH-1. AEMS judges it by AASTP-1.1 3.2.6.2: from the side, square to the wall.

  8. As first drawn, the stack stands 3.0 m inside the wall.

    The 25° line from its top must pass under the whole crest. Here it needs 5.53 m at the far edge; the crest is 5.2 m. AEMS does not count the barricade, so the farm is too close: needs 376 m, has 318.2 m.

  9. Kept 0.5 m from the wall, the barricade counts.

    The line now needs 4.37 m - under the 5.2 m crest. AEMS: "people-protection section OK". The farm needs 235 m and has 318.2 m ✓.

Depot Golf in 3D

Who the lines protect.

  1. 3D illustration: synthetic Depot Golf from high above, with the amber inhabited-building line and the blue vulnerable-building line AEMS draws round it; the village, the school and hospital and a farm lie outside.
    01 AEMS draws the lines. From what is in each storage, AEMS draws two safeguarding lines round the depot: amber for inhabited buildings, blue for vulnerable ones such as schools and hospitals.
  2. 3D illustration: the school SC-1 and the hospital HP-1 in the foreground, the blue vulnerable-building line just beyond them and the depot in the distance.
    02 The school and the hospital stand outside the blue line. Vulnerable buildings get the wider line. Both stand beyond it.
  3. 3D illustration: house H-6 by the road, the amber inhabited-building line passing just short of it and the three open stacks beyond.
    04 House H-6 stands outside the amber line - after the fix. As first drawn an open stack was too close. After the move AEMS advised, the line passes just short of the house.
  4. 3D illustration: open stacks OS-2 and OS-3 with their earth-backed concrete barricades shown see-through; the lines of sight AB run through concrete (white), earth (green) and air (amber): 1 m concrete × 4 + 6.3 m earth = 10.3 m.
    06 Does the barricade count? Lines of sight run from the top of one stack to the other; AEMS adds up the barricade on each. Concrete used with earth counts four times its thickness (AASTP-1 2.2.3.3). AEMS: "BAR-02 with BAR-03: 10.3 m on line AB (1.0 m concrete × 4 + 6.3 m earth), 9.4 m 0.3 m above it".
  5. 3D illustration seen exactly from the side, with the check drawn on the model: the stack 3.0 m inside LW-1's wall, the 25° line from its top passing over BAR-04's 5.2 m crest.
    08 As first drawn, the stack stands 3.0 m inside the wall. The 25° line from its top must pass under the whole crest. Here it needs 5.53 m at the far edge; the crest is 5.2 m. AEMS does not count the barricade, so the farm is too close: needs 376 m, has 318.2 m.
  6. 3D illustration seen exactly from the side: the stack moved to 0.5 m inside the wall; the 25° line now meets the barricade below its crest.
    09 Kept 0.5 m from the wall, the barricade counts. The line now needs 4.37 m - under the 5.2 m crest. AEMS: "people-protection section OK". The farm needs 235 m and has 318.2 m ✓.

3D illustration of synthetic Depot Golf · lines from AEMS b7a732a, 27 Oct 2026, after the fixes · per AASTP-1 Ed D - NOT FOR OPERATIONAL USE

Explainability

Every result shows why.

A distance is only useful if a safety officer can check it. Open any pair and AEMS draws it, names the effect that governs and shows the table column and exposed-site type it was read from.

  1. Measured to scale.

    The pair is drawn as it lies on the site and measured outline to outline: 441.5 m.

  2. Where it comes from.

    The quantity and the table column and exposed-site type the distance was read from: "column 4j · ES 24".

  3. What governs.

    Each effect with its own required distance - blast and debris here - and the one that governs.

  4. Always labelled.

    Every required distance carries the standard it comes from, one click from the full reference.

Real AEMS panel 'Picture: why this distance?' for open stack OS-3 and house H-6: the pair drawn to scale 441.5 m apart, 2,650 kg as HD 1.1, column 4j, ES 24; blast BD31 needs 284 m, debris DFD6 needs 441 m and governs; labelled per AASTP-1 Ed D - NOT FOR OPERATIONAL USE.
Real AEMS screen · synthetic Depot Golf, OS-3 - H-6 after the fixes · AEMS b7a732a · per AASTP-1 Ed D - NOT FOR OPERATIONAL USE

Connected workflow

Plan, check, change, document - in one place.

  1. 01 · Plan

    Draw the site to scale.

    Storages, buildings, roads, fences and barricades on a local metric grid - drawn by hand or from a plan, with doors, rotation and types.

    Real AEMS plan of synthetic Depot Golf: the earth-covered magazine rows A-1 to A-4 and B-1 to B-3, the open stacks OS-1 to OS-3 with their barricades and the internal road.
  2. 02 · Check

    Load the contents, see every limit.

    The inventory comes in from the Excel template AEMS makes for the site. From it AEMS works out each storage's quantity, checks every pair and shows how much each storage may hold - and what limits it.

    Real AEMS Capacity tab for Depot Golf: for each earth-covered magazine the licensable NEQ, the building that limits it and "Within the limit".
  3. 03 · Change

    Ask what to change.

    For a storage that falls short, AEMS proposes moves between the storages you already have - in whole items - and checks the whole site after each one. A draft to check, never applied by itself.

    Real AEMS advice, a draft to check: move DEM-10, 135 items, 1,350 kg, from OS-3 to OS-1, after which both are compliant.
  4. 04 · Document

    Print it for the file.

    The safeguarding map, the QD calculation sheets, the licence proposal, door cards and inspection forms - drafts marked as such, for the qualified officer to check and sign.

    Real AEMS printed door card of Depot Golf, marked as a draft: fire division 1 for earth-covered magazine A-1, what to do in a fire, and the contents.

Documentation

From screen to safety file.

Drafts ready for the qualified officer's check and signature - made from the same site data as the screen.

Real AEMS printed output, marked DRAFT: Safeguarding map for synthetic Depot Golf (first sheet).
Safeguarding mapThe inhabited-building and vulnerable-building lines for the current and the allowed quantities, to scale on the paper you choose.
Real AEMS printed output, marked DRAFT: QD calculation sheet for synthetic Depot Golf (first sheet).
QD calculation sheetOne sheet per potential explosion site (PES), in the layout of the AASTP-1.1 Annex A form: every exposed site, the table cell and the capacity it allows.
Real AEMS printed output, marked DRAFT: Licence proposal for synthetic Depot Golf (first sheet).
Licence proposalAn explosives limits licence proposal per storehouse, laid out after IATG 02.30 - not a licence until the competent authority signs it.
Real AEMS printed output, marked DRAFT: Door card for synthetic Depot Golf (first sheet).
Door cardThe fire division symbol and what is inside, for the door of each storage.
Real AEMS printed output, marked DRAFT: Inspection form for synthetic Depot Golf (first sheet).
Inspection formA checklist per storage with its inspection period and references, printed for the inspector on site.

Real AEMS printed outputs · synthetic Depot Golf · AEMS b7a732a · DRAFT · per AASTP-1 Ed D - NOT FOR OPERATIONAL USE

Engineering trust

Built and checked case by case.

  • 2,460automated tests, all passing on this revision
  • 777rule-data entries, each with a recorded manual check against the standard
  • 12synthetic test depots with hand-checked expected results
  • 10internally accepted demo iterations

Your site stays on your computer. Site data is computed in your browser and saved as a file on your computer. AEMS has no server-side database.

Always labelled. Every distance is labelled with the standard it comes from.

Counted on AEMS 0.11.0 (b7a732a), 27 Oct 2026 · demo software, not for operational use · How AEMS is checked

Talk to us about an evaluation.

A live, screen-shared walkthrough on synthetic sites.

Demo · synthetic data only · not for operational use