AEMS takes an explosives storage site from a drawing to checked, explained and documented quantity-distance (QD) results - drafts for a qualified officer to check and sign. Every screen below is the real app on synthetic Depot Golf.

DEMO · NOT FOR OPERATIONAL USE

01 · Plan

The site, to scale.

The problem: Site plans live in drawings, PDFs and spreadsheets that know nothing of the distance tables.

  • A local metric grid with storages, buildings, roads, power lines, fences and barricades
  • Doors, orientation and earth cover for earth-covered magazines
  • A scanned plan calibrated underneath, to draw over

✓ Available in the current demo

Real AEMS plan of synthetic Depot Golf: two rows of earth-covered magazines, three open stacks with barricades and the internal road.
Real AEMS screen · synthetic Depot Golf · AEMS b7a732a · per AASTP-1 Ed D - NOT FOR OPERATIONAL USE

02 · Assess

Every pair, against AASTP-1.

The problem: Checking each storage against every neighbour by hand is slow, and one missed pair is enough.

  • Closest-point distances for every pair on the site
  • Hazard divisions 1.1 to 1.6, mixing and aggregation under AASTP-1 Ed D.
  • Reduced QD where the standard allows it, and the crater check for HD 1.1 content
  • Each result with an icon and words, never colour alone

✓ Available in the current demo

Real AEMS verdict for open stack OS-3: not compliant, 1 of 29 neighbours too close; H-6 needs 472 m and has 441.5 m.
Real AEMS screen · synthetic Depot Golf · AEMS b7a732a · per AASTP-1 Ed D - NOT FOR OPERATIONAL USE

03 · Explain

Every result shows why.

The problem: A number without its reasoning cannot be checked or signed off.

  • "Picture: why this distance?" for any pair
  • The effect that governs, the table column and the exposed-site type
  • Every distance is labelled with the standard it comes from.

✓ Available in the current demo

Real AEMS "Picture: why this distance?" for OS-3 and H-6: the pair to scale, blast and debris distances, debris governs.
Real AEMS screen · synthetic Depot Golf · AEMS b7a732a · per AASTP-1 Ed D - NOT FOR OPERATIONAL USE

04 · Contents

What is in each storage.

The problem: Quantities and compatibility groups change; the assessment has to follow.

  • An Excel inventory template made for the site, and its loading
  • Net explosive quantity (NEQ) and maximum credible event (MCE) worked out from the items
  • AASTP-1 Table 5 compatibility, with a record where a risk is accepted
  • How much each storage may hold, and what limits it

✓ Available in the current demo

Real AEMS Capacity tab: for each earth-covered magazine of Depot Golf the licensable NEQ, the building that limits it, and "Within the limit".
Real AEMS screen · synthetic Depot Golf · AEMS b7a732a · per AASTP-1 Ed D - NOT FOR OPERATIONAL USE

05 · Change

What should I change?

The problem: Knowing a storage falls short is half the work; finding a fix that does not break another pair is the rest.

  • Moves between the storages you already have, in whole items
  • Each move checked on the whole site, with a preview
  • Where no move works, AEMS says so: a risk acceptance is required
  • A new open stack placed only when you ask

✓ Available in the current demo

Real AEMS advice, a draft to check: move DEM-10, 135 items, 1,350 kg, from OS-3 to OS-1; after it both are compliant.
Real AEMS screen · synthetic Depot Golf · AEMS b7a732a · per AASTP-1 Ed D - NOT FOR OPERATIONAL USE

06 · Safeguarding

See who the lines protect.

The problem: Neighbours, planners and inspectors need to see where the limits fall on the ground.

  • Inhabited-building and vulnerable-building lines for the current and the allowed quantities
  • Whole site or one storage at a time
  • A printable map to scale

✓ Available in the current demo

Real AEMS map of Depot Golf with the safeguarding layer on: the inhabited-building line round the depot.
Real AEMS screen · synthetic Depot Golf · AEMS b7a732a · per AASTP-1 Ed D - NOT FOR OPERATIONAL USE

07 · Documents

From screen to safety file.

The problem: The assessment has to end on paper the officer can check and sign.

  • Excel export and QD calculation sheets in the AASTP-1.1 Annex A layout
  • A licence proposal, the safeguarding map and the emergency plan
  • Door cards with fire division symbols, inspection forms and an inspection plan
  • Every print marked as a draft; the QD sheets carry the program version and the rule-data fingerprint

✓ Available in the current demo

Real AEMS printed licence proposal for Depot Golf, marked DRAFT: explosives limits licence - draft proposal.
Real AEMS screen · synthetic Depot Golf · AEMS b7a732a · per AASTP-1 Ed D - NOT FOR OPERATIONAL USE

08 · Field depot

Deployed ammunition areas.

The problem: Field depots follow their own distances and are set up and changed quickly.

  • AASTP-5 field distances, from a checked rule-data file of their own
  • A separate field page for the compact ammunition area of a deployed mission

◐ In integration

In integration - no screens yet

See it on screen.